US LASER CORP: Product Catalog
Cooling System Parts
Water Pumps, Centrifugal
These close coupled centrifugal water pumps are selected specifically for use in pumping coolant water in laser systems. All parts of the pump exposed to water are plastic or other inert material, and are ideal for use in distilled and deionized water systems. Pumps are available with both single phase and three phase motors, and impeller sizes as listed below. Centrifugal pumps are popular for use in laser systems because of their high water flow capability. The U.S. Laser pump line accommodates most commercial laser systems. Contact the U.S. Laser sales department for special pump requirements.
|
| Part No. |
Description |
| N3111-1 |
3/4 HP single phase centrifugal pump W/ 5 1/2" impeller and 230 VAC motor. |
| N3111-2 |
3/4 HP 3 phase centrifugal pump W/ 5 1/2" impeller and 230 VAC motor |
| N3111-3 |
1 HP 3 phase centrifugal pump W/ 6" impeller and 230 VAC motor |
Water Pump, Turbine
These regenerative turbine water pumps provide an effective alternative to centrifugal pumps when moderate pressure and high flow is desired. The pump housing and impeller are fabricated from 316 stainless steel with Viton seal and ceramic seat. Pumps are available with dual voltage single phase motors, which are typically much lower horsepower than corresponding centrifugal pumps due to the pups higher efficiency. For further information on these pumps for laser applications, please contact the U.S. Laser sales department.
|
| Part No. |
Description |
| N3111-4 |
1/3 HP single phase regenerative turbine pump, 115/208-230 VAC |
| N3111-5 |
3/4 HP three phase regenerating turbine pump, 208-230/460 VAC |
Water Pump Parts
Replacement parts for centrifugal water pumps used in U.S. Laser and other popular laser systems.
|
| Part No. |
Description |
| N3109 |
Water pump shaft seal kit, includes seal and seat |
| N3109-1 |
Water pump seal kit for Regenerative turbine pump No. N3111-4 |
| N3109-2 |
Water pump seal kit for Regenerative turbine pump No. N3111-5 |
| N3109-3 |
Water pump end bell seal and slinger. Fits all USL centrifugal pumps. |
| N3110-1 |
Water pump seal kit with 5 ½" impeller, end bell gasket, and slinger. (Does not include shaft seal No. N3109) |
| N3110-2 |
Water pump seal kit with 6" impeller, end bell gasket, and slinger. (Does not include shaft seal No. N3109) |
| N3110-3 |
Water pump seal kit with S.S. impeller, for Regenerative turbine pump No. N3111-4. |
| N3112-1 |
Replacement 5 ½" impeller for centrifugal pumps |
| N3112-2 |
Replacement 6" impeller for centrifugal pumps |
| N3113-1 |
Replacement 3/4 HP single phase motor for centrifugal pumps |
| N3113-2 |
Replacement 3/4 HP three phase motor for centrifugal pumps |
| N3113-3 |
Replacement 1 HP three phase motor for centrifugal pumps |
| N3114 |
Replacement volute for all U.S. Laser Model N3111 centrifugal pumps |
Heat Exchangers
Heat exchangers are used in laser systems to extract heat from the coolant water using either tap water or a refrigerant. U.S. Laser heat exchangers are fabricated from 304 Stainless steel using the spiral plate design for high efficiency. Two sizes are available, one for heat loads up to 8 KW, and one for heat loads up to 20 KW. For application on systems other than produced by U.S. Laser, contact sales department for further assistance.
|
| Part No. |
Description |
| N4000-850-005 |
8 KW Heat exchanger for U.S. Laser model 403, 404, and 405 laser systems. |
| N4000-850-006 |
20 KW Heat exchanger for U.S. Laser model 406 & 408 laser systems. |
Deionizers
These replacement mixed bed resin deionizers are designed to maintain the electrical integrity of the laser system cooling water by removing unwanted mineral ions. Deionizers should be changed at intervals of 6 months or less depending on system usage.
|
| Part No. |
Description |
| N3101 |
Deionizer cartridge for U.S. Laser systems, (except Markers) 17" body length, hose nipple connections. |
| N3102 |
Deionizer cartridge for U.S. Laser Marker, Control Laser, Holobeam and other systems. 10" body length, hose nipple connections. |
| N3103 |
Special Deionizer cartridge for USL pulsed lasers, 5" body length, 1/4" pipe connections. |
Water Filters
Replacement water filters for U.S. Laser, Control Laser, Holobeam and other laser systems using 9 3/4" elements. Standard filtration rating is 10 µm. For systems using shorter than standard element lengths, filter may be cut to size. Water filters should be replaced every 6 months or sooner, and should be replaced simultaneously with the deionizer cartridge.
|
| Part No. |
Description |
| N3104 |
Water particle filter element, 10 µm, 9 3/4" long |
Proportioning Valves
Proportioning valves are designed to regulate the water temperature in laser cooling systems. When properly installed, coolant water temperature can be maintained to +/- 1 °C. Regulating temperature is factory preset and is not adjustable. Because proportioning valves constantly regulate the water flow, they do not suffer from the severe temperature swings typical from other systems, and are not affected by changing heat load conditions. Valve is constructed from plastic, stainless steel and other inert material to be fully compatible with distilled water. Two valves are available, one for most common laser systems, and one for high powered systems that require higher water flow. If you are unsure of the proportioning valve you need, please contact the U.S. Laser sales dept., we will be glad to assist you in selection of the proper valve.
|
| Part No. |
Characteristics |
| N4000-900-003 |
4 Gallons Per Minute max, 70°F |
| N4000-900-005 |
4 Gallons Per Minute max, 80°F |
| N4000-900-006 |
4 Gallons Per Minute max, 90°F |
| N4000-900-010 |
8 Gallons Per Minute max, 70°F |
| N4000-900-011 |
8 Gallons Per Minute max, 80°F |
| N4000-900-012 |
8 Gallons Per Minute max, 90°F |
Solenoid Valves
Solenoid valves are used on the secondary water side (tap or refrigerated water) of systems equipped with proportioning valves to shut off the system water flow when power is removed. Solenoids are 24 VAC, and have ½" female NPT inlet and outlets.
|
| Part No. |
Description |
| N4000-900-009 |
24 VAC 60 HZ solenoid valve, ½" female NPT inlet and outlet. |
| N4000-900-008 |
24 VAC 50 HZ solenoid valve, ½" female NPT inlet and outlet. |
Flow Switches
These inline flow switches are used in the interlock loop on U.S. Laser laser systems to sense proper coolant flow levels. Switches are constructed of all plastic and stainless steel, and are suitable for use with distilled water coolant. Switches are normally open, and are activated when coolant flows.
|
| Part No. |
Description |
| N8000-500-017 |
Flow switch, ½" Mpt male, 2 GPM |
| N8000-500-023 |
Flow switch, ½" Mpt male, 3 GPM |
Level Switches
Level switches are mounted in the side of the coolant system reservoir, and are used to sense coolant level. Switches are constructed of all plastic and are suitable for use with distilled water.
|
| Part No. |
Description |
| N8000-500-028 |
Level switch |
Temperature Switches
Used in the U.S. Laser interlock loop to protect the system in the event of an over temperature condition. Switches are available in both standard and close tolerance.
|
| Part No. |
Description |
| N8000-500-029 |
Standard temperature switch, 85 °F |
| N8000-500-030 |
Standard temperature switch, 90 °F |
| N8000-500-031 |
Standard temperature switch, 100 °F |
| N8000-500-032 |
Standard temperature switch, 110 °F |
| N8000-500-033 |
Standard temperature switch, 120 °F |
| N8000-500-034 |
Standard temperature switch, 130 °F |
| N8000-500-035 |
Close tolerance temperature switch, 110 °F |
| N8000-500-036 |
Close tolerance temperature switch, 120 °F |
Water Tubing
U.S. Laser stocks a line of plastic water tubing suitable for use with distilled water. Semi-rigid tubing is suitable for medium pressure supply and return lines to the laser head, while the Tygon flexible tubing is primarily used for Q-switch, and other low pressure (<20 PSI) utility uses. Reinforced tubing is good for use at pressures up to 150 PSI. Tubing is sold by length, please specify desired length to the nearest foot.
|
| Part No. |
Description |
| N4000-750-000 |
Poly flow tubing (semi-rigid) ½" O.D. Used for laser head supply lines in lower power U.S. Laser laser systems. |
| N4000-750-004 |
Poly flow tubing (semi-rigid) 5/8" O.D. Used for laser head supply lines in high power U.S. Laser laser systems. |
| N4000-750-006 |
Reinforced 3/4" I.D., 1" nominal O.D. tubing used to supply water from the reservoir to the pump in all U.S. Laser laser systems. |
| N4000-750-007 |
Flexible 3/8" O.D.,1/4" I.D. Tygon style tubing used for power meter and other utility plumbing. |
| N4000-750-008 |
Flexible 1/8" O.D., 1/16" I.D. Tygon style tubing used for Q-Switch and other utility plumbing. |
| N4000-750-009 |
Reinforced 1/4" I.D., 3/8" nominal O.D. tubing used for power meter coolant lines and other general plumbing. |
Water Fittings
U.S. Laser stocks an extensive line of water fittings specifically for use in laser cooling system plumbing. Depending on the area of usage, fitting are available in either nylon, stainless steel, or brass. Nylon and Stainless steel fittings are used on the primary (distilled water) cooling circuit, while brass or nylon fittings are used on the secondary (tap water) side. Consult U.S. Laser sales department for help in selecting the correct fitting.
|
|